Pete, is down to earth, professional, and provides accurate assessments during troubleshooting. Pete never tried to upsale during any of the service visits to our home. He quickly and accurately identified the issue with our A/C unit. Prior to leaving our home Pete did a work around which allowed us to have cool air over the weekend while we waited for the ordered part to arrive to fix our A/C.
Matthew Joeckel was very professional, thorough and clean with the service call. He knew exactly how to troubleshoot the issue and resolve it. I was so impressed that we signed up for the twice a year checkup service agreement.
Very professional and very thorough in explaining everything regarding replacement of both my ac and furnace units. Exceptional service with following up and tweaking the system. Great value and superior customer service.
We had some issues with a few short cuts taken and housekeeping issues. They were immediately addressed. excellent
We needed a specialized AC unit and urgently. SouthCoast got it and brought it to us. No one else was able to do that and we tried several companies. They did their homework! Great help.
Small business owners supporting other small business owners. They follow up and keep to a schedule. Much appreciated.
Found plenum disconnected from coil reconnected plenum back to coil and sealed
Found bad zone damper for upstairs homeowner did not want to replace
Ductwork estimate wants to add 12x6x7 duck and bedroom and in living area and add a 12x12 return air and hallway
System was roughly 1lbs low on r410a, capacitor was also out of range in the condenser unit.
24 volts has brake in the line tired 24 volts together inside and outside and ran a ground from the contactor to the unit unit is currently working checked operations all good
Retaped blower door I forgot to retape it last time I was here blower sucking warm air mixing with cold air created moisture on the bottom of the furnace
Check temperature differential check coil check primary drain pan check plenum for water check ducts for water found grill and lobby vent clothes causing condensation on grill first office grill is Rusty no mold third office grill on inside wall with no insulation system is operating normally
Check blower motor and amperage checked all ductwork checked all electrical connections check primary and secondary drain line found secondary drain pan rusted check amperage on compressor and condenser fan motor check capacitor and contactor check Freon levels
Found compressor not pumping needs to be replaced
Clear drain line Condenser coil needs clean
Installed 2.5 Ton Gas System 16 Seer with Condenser, Coil, Furnace, Drain pan, float switch, drain lines, insulation & 10 Year Parts & Labor.
Checked upstairs and downstairs unit found upstairs unit undercharged unit was installed in December did leak check no leaks found charge unit check downstairs unit no problems found